4 / 17 page Datasheet Datasheet . 4/14 BU1840AMUV TSZ02201-0Q1Q0AJ00130-1-2 © 2012 ROHM Co., Ltd. All rights reserved. 2.AUG.2012 Rev.001 TSZ22111・15・001 www.rohm.com 1. Writing protocol A register address is transferred by the next 1 byte that transferred the slave address and the write-in command. The 3rd byte writes data in the internal register written in by the 2nd byte, and after 4th byte or, the increment of register address is carried out automatically. However, when a register address turns into the last address, it is set to 00h by the next transmission. After the transmission end, the increment of the address is carried out. S A A A P register address slave address from master to slave from slave to master R/W=0(write) DATA A D7 D6 D5 D4 D3 D2 D1 D0 D7 D6 D5 D4 D3 D2 D1 D0 A7 A6 A5 A4 A3 A2 A1 A0 0 X X X X X X X *1 *1 DATA A=acknowledge(SDA LOW) A=not acknowledge(SDA HIGH) S=START condition P=STOP condition *1: Write Timing register address increment register address increment 2. Reading protocol It reads from the next byte after writing a slave address and R/W bit. The register to read considers as the following address accessed at the end, and the data of the address that carried out the increment is read after it. If an address turns into the last address, the next byte will read out 00h. After the transmission end, the increment of the address is carried out. 1 S A P from master to slave from slave to master R/W=1(read) DATA A DATA slave address D7 D6 D5 D4 D3 D2 D1 D0 D7 D6 D5 D4 D3 D2 D1 D0 register address increment X X X X X X X A=acknowledge(SDA LOW) A=not acknowledge(SDA HIGH) S=START condition P=STOP condition register address increment A 3. Multiple reading protocols After specifying an internal address, it reads by repeated START condition and changing the data transfer direction. The data of the address that carried out the increment is read after it. If an address turns into the last address, the next byte will read out 00h. After the transmission end, the increment of the address is carried out. R/W=0(write) R/W=1(read) slave address register address slave address DATA DATA S A A A Sr 1 0 A7 A6 A5 A4 A3 A2 A1 A0 X X X X X X X X X X X X X X A=acknowledge(SDA LOW) A=not acknowledge(SDA HIGH) S=START condition P=STOP condition from master to slave from slave to master register address increment register address increment P A D7D6D5 D4D3D2D1D0 D7D6D5D4D3D2D1D0 A Sr=repeated START condition ※ As for reading protocol and multiple reading protocols, please do A(not acknowledge) after doing the final reading operation. It stops with read when ending by A (acknowledge), and SDA stops in the state of Low when the reading data of that time is 0. However, this state returns usually when SCL is moved, data is read, and A (not acknowledge) is done. |
Ähnliche Teilenummer - BU1840AMUV-E |
|
Ähnliche Beschreibung - BU1840AMUV-E |
|
|
Link URL |
Privatsphäre und Datenschutz |
ALLDATASHEETDE.COM |
War ALLDATASHEET hilfreich? [ DONATE ] |
Über Alldatasheet | Werbung | Kontakt | Privatsphäre und Datenschutz | Linktausch | Hersteller All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |