10 / 18 page 10 - Voltage monitoring relay CM-EFS.2 | Data sheet Voltage window monitoring 2x1 c/o (SPDT) contact i ON-delayed A with latching f Open-circuit principle h The voltage to be monitored (measured value) is applied to terminals B-C. The control supply voltage applied to terminals A1-A2 is displayed by the glowing green LED. If the measured value exceeds the threshold valuemax (>U) or drops below the threshold valuemin (<U), the tripping delay TV starts and the red LED glows (overvoltage), or flashes W (undervoltage) respectively. Timing of TV is displayed by the flashing W green LED. When TV is complete and the measured value still exceeds the threshold valuemax minus the fixed hysteresis (5 %) or is still below the threshold valuemin plus the fixed hysteresis (5 %), the output relay 1115-1216/1418 (>U), or 2125-2226/2428 (<U) respectively, energizes and the yellow LED (relay energized) flashes Z. If the measured value decreases below the threshold valuemax minus the fixed hysteresis (5 %) or exceeds the threshold valuemin plus the fixed hysteresis (5 %), the red LED turns off. The output relay 1115-1216/1418 (>U), or 2125-2226/2428 (<U) respectively, remains energized (latching function). If control supply voltage is interrupted (reset), the output relay 1115-1216/1418 (>U), or 2125-2226/2428 (<U) respectively, de- energizes and the yellow and green LEDs turn off. Closed-circuit principle g The voltage to be monitored (measured value) is applied to terminals B-C. When control supply voltage is applied to terminals A1-A2, the output relays energize and the green and yellow LED (relays energized) glow. If the measured value exceeds the threshold valuemax (>U) or drops below the threshold valuemin (<U), the tripping delay TV starts and the red LED glows (overvoltage), or flashes W (undervoltage) respectively. Timing of TV is displayed by the flashing W green LED. When TV is complete and the measured value still exceeds the threshold valuemax minus the fixed hysteresis (5 %) or is still below the threshold valuemin plus the fixed hysteresis (5 %), the output relay 1115-1216/1418 (>U), or 2125-2226/2428 (<U) respectively, de-energizes and the yellow LED (relays energized) flashes Y. If the measured value decreases below the threshold valuemax minus the fixed hysteresis (5 %) or exceeds the threshold valuemin plus the fixed hysteresis (5 %), the red LED turns off. The output relay 1115-1216/1418 (>U), or 2125-2226/2428 (<U) respectively, remains de-energized (latching function). If control supply voltage is interrupted (reset), the yellow and green LEDs turn off. The output relays energize again when control supply voltage is re-applied. A1-A2 >U: 11-14 (15-18) 11-12 (15-16) <U: 21-24 (25-28) 21-22 (25-26) >U: 11-14 (15-18) 11-12 (15-16) <U: 21-24 (25-28) 21-22 (25-26) open closed Thresholdmax Hysteresis green LED red LED yellow LED green LED red LED yellow LED Open-circuit principle Closed-circuit principle TV < TV Hysteresis Measured value Thresholdmin TV Reset < TV |
Ähnliche Teilenummer - 1SVR730005R0100 |
|
Ähnliche Beschreibung - 1SVR730005R0100 |
|
|
Link URL |
Privatsphäre und Datenschutz |
ALLDATASHEETDE.COM |
War ALLDATASHEET hilfreich? [ DONATE ] |
Über Alldatasheet | Werbung | Kontakt | Privatsphäre und Datenschutz | Linktausch | Hersteller All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |