Datenblatt-Suchmaschine für elektronische Bauteile |
|
TS5A3159-Q1 Datenblatt(PDF) 2 Page - Texas Instruments |
|
TS5A3159-Q1 Datenblatt(HTML) 2 Page - Texas Instruments |
2 / 25 page TS5A3159-Q1 SCDS336A – NOVEMBER 2012 – REVISED DECEMBER 2012 www.ti.com Table 2. Summary of Characteristics V+ = 5 V and TA = 25°C 2:1 Multiplexer / Demultiplexer Configuration (1 × SPDT) Number of channels 1 ON-state resistance (ron) 1.3 Ω ON-state resistance match ( Δron) 0.1 Ω ON-state resistance flatness (ron(flat)) 0.15 Ω Turn on/turn off time (tON / tOFF) 20 ns / 15 ns Break-before-make time (tBBM) 12 ns Charge injection (QC) 36 pC Bandwidth (BW) 100 MHz OFF isolation (OISO) –65 dB at 1 MHz Crosstalk (XTALK) –65 dB at 1 MHz Total harmonic distortion (THD) 0.01% Leakage current (INO(OFF) / INC(OFF)) ±6 nA Package option 6-pin DBV ORDERING INFORMATION(1) TA ORDERABLE PART NUMBER(2) TOP-SIDE MARKING –40°C to 125°C TS5A3159QDBVRQ1 UAAQ (1) Package drawings, thermal data, and symbolization are available at www.ti.com/packaging. (2) For the most current package and ordering information, see the Package Option Addendum at the end of this document, or see the TI web site at www.ti.com. ABSOLUTE MAXIMUM RATINGS (1) over operating free-air temperature range (unless otherwise noted) MIN MAX UNIT V+ Supply voltage range(2) –0.5 6.5 V VNO, VCOM Analog voltage range(2)(3)(4) –0.5 V+ + 0.5 V II / OK Analog port diode current VNO, VCOM < 0 or VNO, VCOM > V+ ±50 mA INO, ICOM ON −state switch current VNO, VCOM = 0 to V+ ±200 mA ON −state peak switch current(5) ±400 mA VIN Digital input voltage range(2)(3) −0.5 6.5 V IIK Digital input clamp current VIN < 0 −50 mA Continuous current through V+ or GND ±100 mA Tstg Storage temperature range –65 150 °C Human body model (HBM) AEC-Q100 classification level H2 2 kV ESD Rating Charged device model (CDM) AEC-Q100 classification level C3B 750 V (1) Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated under Recommended Operating Conditions is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability. (2) All voltages are with respect to ground, unless otherwise specified. (3) The input and output voltage ratings may be exceeded if the input and output clamp-current ratings are observed. (4) This value is limited to 5.5 V maximum. (5) Pulse at 1 ms duration < 10% duty cycle. 2 Submit Documentation Feedback Copyright © 2012, Texas Instruments Incorporated Product Folder Links: TS5A3159-Q1 |
Ähnliche Teilenummer - TS5A3159-Q1_15 |
|
Ähnliche Beschreibung - TS5A3159-Q1_15 |
|
|
Link URL |
Privatsphäre und Datenschutz |
ALLDATASHEETDE.COM |
War ALLDATASHEET hilfreich? [ DONATE ] |
Über Alldatasheet | Werbung | Kontakt | Privatsphäre und Datenschutz | Linktausch | Hersteller All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |