Datenblatt-Suchmaschine für elektronische Bauteile |
|
U1280 Datenblatt(PDF) 8 Page - Keysight Technologies |
|
U1280 Datenblatt(HTML) 8 Page - Keysight Technologies |
8 / 18 page 08 | Keysight | U1280 Series Handheld Digital Multimeters - Data Sheet General specifications Display 5-digit liquid crystal display (LCD) with maximum reading of 66,000-count Automatic polarity indication. Power consumption 250 mVA / 330 mVA with backlight Battery type 4x 1.5 V AA alkaline battery (ANSI/NEDA 15A or IEC LR6), or; 4x 1.5 V AA zinc chloride battery (ANSI/NEDA 15D or IEC R6), or; 4x 1.5 V AA Lithium battery (ANSI/NEDA 15-LF or IEC FR6) Battery life 800 hours typical based on new alkaline batteries for DC voltage measurement Connectivity Infrared (IR) port, connect with: – IR-USB cable, or; – U1117A IR-to-Bluetooth adapter (Bluetooth Class 1), or; – U1177A IR-to-Bluetooth adapter (Bluetooth Class 2) Fuse 10 x 35 mm, 440 mA / 1000 V, 10 kA minimum fast-acting fuse 10 x 38 mm, 11 A / 1000 V, 20 kA minimum fast-acting fuse Operating environment Full accuracy from –20 °C to 55 °C; and up to 80 % R.H. for temperature up to 30 °C decreasing linearly to 50 % R.H. at 55 °C Pollution Degree II Altitude up to 3000 meters Storage compliance –40 °C to 70 °C, 0 to 80 % R. H. (with battery removed) Safety compliance EN/IEC 61010-2-030: 2010 EN/IEC 61010-1: 2010 Measurement category CAT III 1000 V / CAT IV 600 V Electromagnetic compatibility (EMC) Susceptibility and Emissions: commercial limits per EN/IEC 61326-1 Ingression protection rating IP-67, protected against dust and the effect of immersion between 15 cm and 1 m Temperature coefficient 0.05 x (specified accuracy) / °C (from –20 °C to 18 °C or 28 °C to 55 °C) Common mode rejection ratio (CMRR) > 120 dB at DC, 50/60 Hz ± 0.1 % (1 kΩ unbalanced) Normal mode rejection ratio (NMRR) > 60 dB at 50/60 Hz ± 0.1 % Dimensions (H x W x D) 218 x 96 x 59 mm Weight 701 grams (with batteries) Warranty Three years for main unit Three months for standard shipped accessories Calibration cycle One year, or; Two years (with 1.5 times of one year specification) Specification assumptions – Accuracy is given as ± (% of reading + counts of least significant digit) at 23 °C ± 5 °C, with relative humidity less than 80 % R.H. – Accuracy is specified for 1-year after calibration, at operating temperature of room temperature. Multiply 1.5 times of the accuracy for 2-year after calibration. Example ± (1.5 X % of reading + 1.5 X counts of least significant digit). – AC and AC µA / mA / A specifications are AC coupled. – True RMS measurement is valid from 5 % of range to 100 % of range. – For non-sinusoidal waveforms, add (0.1 % of reading + 0.3 % of full scale) typically – The maximum circuit limitation of peak signal is 300 % typically for voltage and current except 250 % and 150 % typically for range 600 V and 1000 V respectively. – The crest factor is according to the maximum circuit limitation of peak signal – Specification is based on 5 times/second of data refresh rate – CMRR and NMRR are based on 5 times/second of data refresh rate |
Ähnliche Teilenummer - U1280 |
|
Ähnliche Beschreibung - U1280 |
|
|
Link URL |
Privatsphäre und Datenschutz |
ALLDATASHEETDE.COM |
War ALLDATASHEET hilfreich? [ DONATE ] |
Über Alldatasheet | Werbung | Kontakt | Privatsphäre und Datenschutz | Linktausch | Hersteller All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |