Datenblatt-Suchmaschine für elektronische Bauteile |
|
UZK24.121 Datenblatt(PDF) 4 Page - PULS GmbH |
|
UZK24.121 Datenblatt(HTML) 4 Page - PULS GmbH |
4 / 11 page UZK24.121, UZO24.121 U-Series BATTERY MODULE 24V, 12AH Connect the sensor board to the DC-UPS by using control wires with a minimum wire size of 0.5mm2 / 20AWG. Install the device in an enclosure providing protection against electrical, mechanical and fire hazards. Ensure sufficient ventilation by following the requirements of the EN 50272-2. CAUTION: The unit contains wet cell batteries. Ventilation of the installation room in accordance with the rules of Canadian Electrical Code, part 1 is required if used in Canada. The battery module is for use in a controlled environment. Do not use the device in pollution degree 3 areas without additional protection or in applications where a degree of protection better than IP00 is required. Do not use batteries other than the original batteries supplied by the manufacturer to avoid conflicts with agency approvals. The maximum surrounding air temperature is +50°C / +122°F. The operational temperature is the same as the ambient or surrounding air temperature and is defined as the air temperature 2cm below the device. Fig. 8-1 Wiring scheme Battery DC-UPS Data/ Temp. (11) RTN (12) Center Tap (13) X1 (+) X2 (-) Battery wires (+) ( -) X1 UZK24.121 Battery Module Temp. (11) RTN (12) Center Tap (13) optional Load Output Input (+) (-) 9. HAZARDOUS LOCATION INSTALLATION INSTRUCTIONS The device is suitable for use in Class I Division 2 Groups A, B, C, D locations and for use in Group II Category 3 (Zone 2) environments. ATEX Certificate: EPS 15 ATEX 1 025 X ATEX Classification: II 3G EX ec IIC T4 Gc WARNING EXPLOSION HAZARDS! Substitution of components may impair suitability for this environment. Do not disconnect the device unless power has been switched off or the area is known to be non-hazardous. A suitable enclosure must be provided for the end product which has a minimum protection of IP23 and fulfils the requirements of the EN 60079-15. Sufficient ventilation must be ensured in the final installation. Do not use batteries other than the original batteries supplied by the manufacturer or batteries, which are approved according to EN/ IEC 60079-7. Aug. 2017 / Rev. 2.0 DS-UZK24.121-EN All parameters are typical values specified at, 25°C ambient temperature unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 Germany 4/11 |
Ähnliche Teilenummer - UZK24.121_17 |
|
Ähnliche Beschreibung - UZK24.121_17 |
|
|
Link URL |
Privatsphäre und Datenschutz |
ALLDATASHEETDE.COM |
War ALLDATASHEET hilfreich? [ DONATE ] |
Über Alldatasheet | Werbung | Kontakt | Privatsphäre und Datenschutz | Linktausch | Hersteller All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |