Datenblatt-Suchmaschine für elektronische Bauteile |
|
BQ79600-Q1 Datenblatt(PDF) 45 Page - Texas Instruments |
|
BQ79600-Q1 Datenblatt(HTML) 45 Page - Texas Instruments |
45 / 71 page 7.5.16 Register: FAULT_REG Address: 0x2101 B7 B6 B5 B4 B3 B2 B1 B0 RSVD CONF_MON_ERR FACTLDERR FACT_CRC 0 0 0 0 0 0 0 0 R R R R R R R R CONF_MON_ER R Indicates monitored 2 registers (DEV_CONF1, FAULT_MSK) have at least one bit flip. For usage, refer to paragraph: Register Bit Flip Monitor. 0: No fault 1: Fault FACTLDERR Indicates the factory NVM registers could not be loaded from OTP. 0: No fault 1: Fault FACT_CRC Indicates a CRC error has occurred in the factory register space. 0: No fault 1: Fault 7.5.17 Register: FAULT_SYS Address: 0x2102 B7 B6 B5 B4 B3 B2 B1 B0 VALIDATE_DET LFO SHUTDOWN_REC DRST CTL CTS TSHUT INH 0 0 0 0 0 0 0 0 R R R R R R R R VALIDATE_DET Indicates device transitioned to VALIDATE mode 0: no transitioned to VALIDATE MODE 1: transitioned to VALIDATE MODE LFO Indicated LFO frequency is off by +/-25% 0: no fault 1: fault SHUTDOWN_RE C Indicates the device was shut down using SHUTDOWN ping. If this bit is set, the COML and COMH RX are both disabled at wake up as a way to isolate itself from the stack. Send another wake ping or [SOFT_RESET] to re-enable COMH/L RX. 0: The previous SHUTDOWN was normal 1: The previous SHUTDOWN was caused by ping, which is not a usual SHUTDOWN method, indicating potential communication issue with the device DRST Indicates a digital reset has occurred. 0: no digital reset 1: digital reset has occurred CTL Indicates a long communication timeout occurred. Device action is configured by [CTL_ACT]. This bit is not observable if the action is set to device shutdown. 0: No fault 1: long communication timeout occurs. Observable if long timeout action is set to SLEEP CTS Indicates a short communication timeout occurred. No action from the device. This can be served as an alert to system before reaching long communication timeout. 0: No fault 1: short communication timeout occurs TSHUT Indicates the previous shutdown was due to thermal shutdown 0: die temp is < thermal shutdown threshold 1: the previous shutdown was to due thermal shutdown INH Indicates INH PMOS is enabled 0: INH driver is off 1: INH driver enabled, pulls pin up to BAT www.ti.com BQ79600-Q1 SLUSDS1A – NOVEMBER 2019 – REVISED AUGUST 2020 Copyright © 2020 Texas Instruments Incorporated Submit Document Feedback 45 Product Folder Links: BQ79600-Q1 |
Ähnliche Teilenummer - BQ79600-Q1_V01 |
|
Ähnliche Beschreibung - BQ79600-Q1_V01 |
|
|
Link URL |
Privatsphäre und Datenschutz |
ALLDATASHEETDE.COM |
War ALLDATASHEET hilfreich? [ DONATE ] |
Über Alldatasheet | Werbung | Kontakt | Privatsphäre und Datenschutz | Linktausch | Hersteller All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |