6 / 7 page
6.4 Endurance
Item
Te s t C o n d i t i o n s
Require me n t s
6.4.1.
Operating Life
Measurements shall be made following the test set
forth below:
(1)DC 5V 5mA resistive load
(2)Rate of operation: 2 to 3 operations per second
(3)Depression:
300
g f
(4)Cycles of operation:
10 x10
4
cycles
Contact resistance:
200
m ohm max.
Insulation resistance:
10
M ohm min.
Bounce:
10
m sec
max.
Actuating force:
+ 30 % or
- 30 % of initial
force
Item
6.1.3
Item
6.2.2
6.4.2.
Vibration
Resistance
Measurements shall be made following the test set
forth below:
(1)Range of oscillation: 10 to 55 Hz
(2)Amplitude, pk-to-pk:1.5 mm
(3)Cycle of sweep: 10 -55 -10 Hz in one minute,
approx.
(4)Mode of sweep: Logarithmically sweep or
uniform sweep
(5)Direction of oscillation:
Three mutually perpendicular directions,
including the direction of stem travel
(6)Duration of testing:
2 hours each, for a total of 6 hours
Item
6.1
Item
6.2.1
Item
6.2.2
6.4.3.
Impact Shock
Resistance
Measurements shall be made following the test set
forth below:
(1)Acceleration:80g
(2)Cycles of test:3 cycles each in 6 directions, for a
total of 18 cycles
Item
6.1
Item
6.2.1
Item
6.2.2
PART NO: