Datenblatt-Suchmaschine für elektronische Bauteile
  German  ▼
ALLDATASHEETDE.COM

X  

KMA200 Datenblatt(PDF) 8 Page - NXP Semiconductors

Teilenummer KMA200
Bauteilbeschribung  Programmable angle sensor
Download  31 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Hersteller  PHILIPS [NXP Semiconductors]
Direct Link  http://www.nxp.com
Logo PHILIPS - NXP Semiconductors

KMA200 Datenblatt(HTML) 8 Page - NXP Semiconductors

Back Button KMA200 Datasheet HTML 4Page - NXP Semiconductors KMA200 Datasheet HTML 5Page - NXP Semiconductors KMA200 Datasheet HTML 6Page - NXP Semiconductors KMA200 Datasheet HTML 7Page - NXP Semiconductors KMA200 Datasheet HTML 8Page - NXP Semiconductors KMA200 Datasheet HTML 9Page - NXP Semiconductors KMA200 Datasheet HTML 10Page - NXP Semiconductors KMA200 Datasheet HTML 11Page - NXP Semiconductors KMA200 Datasheet HTML 12Page - NXP Semiconductors Next Button
Zoom Inzoom in Zoom Outzoom out
 8 / 31 page
background image
9397 750 11399
© Koninklijke Philips Electronics N.V. 2005. All rights reserved.
Product data sheet
Rev. 05 — 16 August 2005
8 of 31
Philips Semiconductors
KMA200
Programmable angle sensor
7.
Outputs of KMA200
The output of the KMA200 is either digital or analog, depending on the control word stored
in the EEPROM. The analog output consists of a standard and a programmable output
stage. The programmable output stage allows four different characteristics; mode 1,
mode 2, mode 3 or none output. The digital output has two different modes; mode 5 and
mode 6.
Analog output
In the analog output mode the measured angle value is converted linear into a value that
is ratio metric to the supply voltage VDD. This voltage is driven by the standard output
stage to pin OUT1. The same value is fed to a second output stage that is connected to
pin OUT2. This second output stage is programmable to one of four different output
characteristics; mode 1, mode 2, mode 3 or high-impedance state output.
A valid angle value is nominally mapped to an output voltage range of V(CL)l (default =
5 %) to V(CL)u (default = 95 %) of VDD at the standard output VOUT1 (see Figure 3).
For mode 1 the valid output voltage range at pin OUT2 is identical to the output voltage
range of the standard analog voltage but the output characteristic is inverted
(see Figure 4).
In mode 2 (see Figure 5) the valid output range at pin OUT2 is nominally V(CL)l/2 to
V(CL)u/2 of VDD.
A further possibility is to program the VOUT2 (mode 3, αthresh) as a comparator depending
from the angle value (see Figure 6).
When the KMA200 detects an error condition, it switches the analog outputs into
high-impedance state. The outputs are forced to lie in the upper or lower diagnostic range
by the external pull-up or pull-down resistors.
Table 5:
Setting the KMA200 output characteristics
Output
characteristics
Pin assignment
Mode setting of EEPROM
(ctrl1)
Mode
Type
DATA/OUT1
CLK/OUT2
OM2
OM1
OM0
Mode 1
analog
standard
inverted
1
0
0
Mode 2
analog
standard
half range
1
0
1
Mode 3
analog
standard
comparator
1
1
0
Mode 4
analog
standard
high-impedance
state
111
Mode 5
digital
serial data (SPI)
(clock)
0
0
0
Mode 6
digital
bit complement
serial data (SPI)
(clock)
0
0
1


Ähnliche Teilenummer - KMA200

HerstellerTeilenummerDatenblattBauteilbeschribung
logo
NXP Semiconductors
KMA200 NXP-KMA200 Datasheet
163Kb / 32P
   Programmable angle sensor
Rev. 07-18 July 2008
KMA200 PHILIPS-KMA200 Datasheet
278Kb / 33P
   Programmable angle sensor
Rev. 8-7 December 2011
KMA200 PHILIPS-KMA200_11 Datasheet
278Kb / 33P
   Programmable angle sensor
Rev. 8-7 December 2011
More results

Ähnliche Beschreibung - KMA200

HerstellerTeilenummerDatenblattBauteilbeschribung
logo
NXP Semiconductors
KMA199E NXP-KMA199E Datasheet
166Kb / 31P
   Programmable angle sensor
Rev. 01-18 October 2007
KMA221 NXP-KMA221 Datasheet
566Kb / 36P
   Programmable angle sensor
Rev. 1-16 July 2013
KMA199 NXP-KMA199 Datasheet
595Kb / 36P
   Programmable angle sensor
Rev. 01-26 April 2010
KMA200 NXP-KMA200 Datasheet
163Kb / 32P
   Programmable angle sensor
Rev. 07-18 July 2008
KMA210-115 NXP-KMA210-115 Datasheet
591Kb / 37P
   Programmable angle sensor
Rev. 2-7 December 2011
KMA200 PHILIPS-KMA200_11 Datasheet
278Kb / 33P
   Programmable angle sensor
Rev. 8-7 December 2011
logo
Micronas
HAL3625 MICRONAS-HAL3625 Datasheet
215Kb / 2P
   Programmable Direct Angle Sensor
logo
NXP Semiconductors
KMA310 NXP-KMA310 Datasheet
888Kb / 71P
   Programmable angle sensor IC
Rev. 3-27 February 2019
KMZ80 NXP-KMZ80 Datasheet
937Kb / 71P
   Programmable angle sensor IC
Rev. 2.1-4 July 2018
KMA321 NXP-KMA321_V01 Datasheet
1Mb / 71P
   Programmable angle sensor IC
Rev. 6 ??18 May 2022
More results


Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31


Datenblatt Download

Go To PDF Page


Link URL




Privatsphäre und Datenschutz
ALLDATASHEETDE.COM
War ALLDATASHEET hilfreich?  [ DONATE ] 

Über Alldatasheet   |   Werbung   |   Kontakt   |   Privatsphäre und Datenschutz   |   Linktausch   |   Hersteller
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com