Datenblatt-Suchmaschine für elektronische Bauteile |
|
UWE-5-20-Q48PB-C Datenblatt(PDF) 3 Page - Murata Manufacturing Co., Ltd. |
|
UWE-5-20-Q48PB-C Datenblatt(HTML) 3 Page - Murata Manufacturing Co., Ltd. |
3 / 13 page UWE Series Wide Input, Isolated Eighth-Brick DC/DC Converters Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000 www.murata-ps.com MDC_UWE Series.A17 Page 3 of 20 DETAIL SPECIFICATIONS, Q12 MODELS, CONTINUED INPUT (continued) UWE-3.3/20-Q12 UWE-5/15-Q12 UWE-12/6-Q12 UWE-15/5-Q12 UWE-24/3-Q12 (Off, UV, OT shutdown) Internal input filter type L-C Reverse polarity protection Yes Remote On/Off control Positive logic ("P" model suffix) OFF=Ground pin to +0.8V max. ON=open pin or +3.5 to +15V max. Negative logic ("N" model suffix) OFF=open pin or +5V to +15V max. ON=Ground pin or 0 to +0.8V max. Current, mA 1 OUTPUT Voltage output range See ordering guide Voltage output accuracy ±1% of Vnom., (50% load) Adjustment range -10 to +10% of Vnom. Temperature coefficient ±0.02% of Vout range per °C Minimum loading No minimum load Remote sense compensation +10% max. Ripple/noise (20 MHz bandwidth) See ordering guide Line/Load regulation See ordering guide Efficiency See ordering guide Maximum capacitive loading, μF low ESR <0.02Ω max., resistive load 10,000 10,000 4,700 4700 1500 Isolation voltage Input to Output, Volts min. DC 1500 Input to baseplate, Volts min. DC 1500 Baseplate to output, Volts min. DC 750 Isolation resistance, MΩ 100 Isolation capacitance, pF 1500 1000 1000 1000 1000 Isolation safety rating Basic insulation Current limit inception (98% of Vout, after warmup), Amps 27 22.5 8.5 7.25 4.0 Short circuit protection method Current limiting, hiccup autorestart. Remove overload for recovery. Short circuit current, Amps 0.5 1.0 1.5 1.5 1.0 Short circuit duration Continuous, output shorted to ground. No damage. Overvoltage protection, Volts (via magnetic feedback) 4.5 6 151829 DYNAMIC CHARACTERISTICS Dynamic load response, μSec (50-75-50% load step) to ±1% of final value 50 Start-up time Vin to Vout regulated, mSec 20 20 40 30 40 Remote On/Off to Vout regulated, mSec 5 15302530 Switching frequency, KHz 245 ±25 215-250 275 ±25 275 ±25 215 ±15 |
Ähnliche Teilenummer - UWE-5-20-Q48PB-C |
|
Ähnliche Beschreibung - UWE-5-20-Q48PB-C |
|
|
Link URL |
Privatsphäre und Datenschutz |
ALLDATASHEETDE.COM |
War ALLDATASHEET hilfreich? [ DONATE ] |
Über Alldatasheet | Werbung | Kontakt | Privatsphäre und Datenschutz | Linktausch | Hersteller All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |