Datenblatt-Suchmaschine für elektronische Bauteile |
|
BAT-1270 Datenblatt(PDF) 1 Page - Gamewell-FCI by Honeywell |
|
BAT-1270 Datenblatt(HTML) 1 Page - Gamewell-FCI by Honeywell |
1 / 4 page GWACCZ CS-2505 09/01/06 Page 1 of 4 Description Gamewell’s Zoned Audio Command Center (GWACCZ) is a state-of-the-art Emergency Voice Evacuation Panel (EVAC) capable of splitting 25 or 50 watts of audio power into up to eight speaker circuits (i.e., zones). The GWACCZ provides the ability to record five field-programmable messages (up to 60 seconds total message duration) with an integral commercial-grade emergency communications micro- phone or from an external audio source. Significant technological enhancements set the GWACCZ apart from other EVAC panels — these include full su- pervision in both active alarm and standby conditions, supervision of am- plifier outputs, field wiring, message generator, all tone generators, and the microphone. The integral power supply is capable of charging up to 18 AH bat- teries, which can be housed in the GWACCZ cabinet. The GWACCZ is suitable for use as an adjunct (slave or stand-alone) to most UL- Listed Fire Alarm Control Panels (FACPs). An optional 25 watt, 25 VRMS audio amplifier is available for system expansion to 50 watts or as a secondary amplifier in jurisdictions requiring such backup. A 70.7 VRMS converter is also available for independently converting amplifiers to meet retrofit needs. The Zone Splitter Module (ACC-ZSM) divides the output of the Audio Amplifier Module(s) (ACC-AAM25) into up to eight speaker circuits (i.e., zones). The Zone Page Module with Keypad (ACC-ZPMK) provides full manual control of the speaker circuits, status indication of each of the speaker circuits, and automatic control by the FACP via the ACS serial link connection. A host of field-programming options, including the capability of five custom messages (fire, tornado, evacuation, hazmat, non-fire, multi-language, etc.) make the GWACCZ the most versatile voice evacuation system available. Some suitable applications for the GWACCZ include schools, auditoriums, dormitories, theatres, restaurants, places of worship, lodging, office build- ings, and factories. Controls and Indicators 1. Power On (green). Standard Features • 25 watts of audio power can be divided into eight Style Y (Class B) or four Style Z (Class A) speaker circuits (zones), utilizing the zone splitter module (ACC-ZSM). • Full manual control of all audio zones provided by zone page module with keypad (ACC-ZPMK). • Activation by the FACP using the ACS serial link and/or the five Command (CMD) inputs. • ACS serial link compatible with all Gamewell FACPs, depending on function. FACP automati- cally directs the voice message to each or all audio zones. • Paging by zone or All-Call. • Full status indication (normal, active, fault) of each speaker circuit. • Fault indication via ACS serial link and/or the two Form-C trouble relays (System & AC Power Loss). • Integral 25 watt, 25 VRMS audio amplifier with single Style Z (Class A) or Style Y (Class B) speaker circuit (expandable to 50 watts using the ACC-AAM25). • Modular design for maximum system flexibility and ease-of-service. • Two command input circuits can be independently field-programmed for activation by a Notification Appliance Circuit (NAC) or contact closure. • Three command input circuits activate on contact closure. • ACS link or Command Input (CMD) allow: one 60-second message; two 30-second messages; three 20-second messages; four 15- second messages; or five 12-second messages. • Microphone time-out feature. • Nineteen different system and diagnostic LEDs. • Two Form-C trouble relays (System/AC Power Loss). • Optional equipment: second amplifier; local playback speaker; remote microphone; and paging equipment interface. • Integral digital message generator with standard, factory-prerecorded emergency evacuation message. • Custom messages are field recordable, without the addition of costly add-on modules, utilizing the integral microphone or the audio input jack. • Digital message may be field-selected for 3, 4, 6, 8, or infinite repeat. • Built-in alert tone generators with steady, slow whoop, high/low, or chime tone capability. • Field-selectable lead-in/trailing tone selection. • Alert tone selection may be field-programmed to conform with ANSI S3.41 Audible Emergency Evacuation Signal (Temporal Pattern), per NFPA. • Speaker zone control via ACS serial link, CMD inputs or keypad. • Dual-optically-isolated, trigger input circuits are independently field-programmable for activation by polarity reversal (host FACP NAC) or dry-contact closure. • Integral diagnostic LEDs include: Power, System Trouble, Microphone Trouble, Message Generator Trouble, Tone Generator Trouble, Amplifier Fault, and others. • ACS serial link or independent Form-C trouble relay allows FACP to monitor voice system while in active (alarm) state. • Integral piezo provides local audible indication for troubles. • Fully supervised in Standby and Active states, including integral microphone, amplifier output, message generator, speaker wiring, and tone generators. • Independent amplifier supervision: current limit, audio level, short circuit protection. • All outputs are power-limited. • Auxiliary power output provides local power for addressable control modules when used to activate the GWACCZ. • Compatible with all Gamewell FACPs, as well as other manufacturers’ panels. GWACCZ Zoned Audio Command Center Voice Evacuation Control Panel g2504ph1.jpg |
Ähnliche Teilenummer - BAT-1270 |
|
Ähnliche Beschreibung - BAT-1270 |
|
|
Link URL |
Privatsphäre und Datenschutz |
ALLDATASHEETDE.COM |
War ALLDATASHEET hilfreich? [ DONATE ] |
Über Alldatasheet | Werbung | Kontakt | Privatsphäre und Datenschutz | Linktausch | Hersteller All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |