Datenblatt-Suchmaschine für elektronische Bauteile |
|
MC20XS4200 Datenblatt(PDF) 8 Page - Freescale Semiconductor, Inc |
|
MC20XS4200 Datenblatt(HTML) 8 Page - Freescale Semiconductor, Inc |
8 / 60 page Analog Integrated Circuit Device Data 8 Freescale Semiconductor 20XS4200 ELECTRICAL CHARACTERISTICS STATIC ELECTRICAL CHARACTERISTICS STATIC ELECTRICAL CHARACTERISTICS Table 3. Static Electrical Characteristics Unless specified otherwise: 8.0 V ≤ V PWR ≤ 36 V, 3.0 V ≤ VDD ≤ 5.5 V, - 40 °C ≤ TA ≤ 125 °C, GND = 0 V. Typical values are average values evaluated under nominal conditions TA = 25 °C, VPWR = 28 V & VDD = 5.0 V, unless specified otherwise. Parameter Symbol Min Typ Max Unit SUPPLY ELECTRICAL CHARACTERISTICS Supply Voltage Range: Full Specification compliant Extended Mode(10) VPWR 8.0 6.0 24 – 36 58 V VPWR Supply Current, device in wake-up mode, channel On, open-load Outputs in ON-state, HS[0:1] open, IN[0:1] > VIH IPWR(ON) – 6.5 8.0 mA VPWR Supply Current, device in wake-up mode (Standby), channel Off open-load in OFF-state detection disabled, HS[0:1] shorted to ground with VDD = 5.5 V and RSTB > VWAKE IPWR(SBY) – 6.5 8.0 mA Sleep State Supply Current VPWR = 24 V, RSTB = IN[0:1] < VWAKE, HS[0:1] connected to ground TA = 25 °C TA = 125 °C IPWR(SLEEP) – – 3.0 – 10.0 60.0 μA VDD Supply Voltage VDD(ON) 3.0 – 5.5 V VDD Supply Current at VDD = 5.5 V No SPI Communication 8.0 MHz SPI Communication(11) IDD(ON) – – – 5.0 2.2 – mA VDD Sleep State Current at VDD = 5.5 V with or without VPWR IDD(SLEEP) – – 5.0 μA Over-voltage Shutdown Threshold VPWR(OV) 39 42 45.5 V Over-voltage Shutdown Hysteresis VPWR(OVHYS) 0.2 0.8 1.5 V Under-voltage Shutdown Threshold(12) VPWR(UV) 5.0 – 6.0 V VPWR Power-On-Reset (POR) Voltage Threshold (12) VPWR(POR) 2.2 2.6 4.0 V VDD Power-On-Reset (POR) Voltage Threshold (12) VDD(POR) 1.5 2.0 2.5 V VDD Supply Failure Voltage Threshold (assumed VPWR > VPWR(UV)) VDD(FAIL) 2.2 2.5 2.8 V Notes 10. In extended mode, availability of several device functions (channel control, value of RDS(ON), over-temperature protection) is guaranteed, but compliance with the specified values in this document is not. Below 6.0 V, the device is only protected from overheating (thermal shutdown). Above VPWR(OV), the channels can only be turned ON when the over-voltage detection function has been disabled. 11. Typical value guaranteed per design. 12. When the device recovers from under-voltage and returns to normal mode (6.0 V < VPWR < 58 V) before the end of the auto-retry period (see Auto-retry), the device will perform normally. When VPWR drops below VPWR(UV), under-voltage is detected (see Under-voltage Fault (Latchable Fault) and EMC Performances). |
Ähnliche Teilenummer - MC20XS4200 |
|
Ähnliche Beschreibung - MC20XS4200 |
|
|
Link URL |
Privatsphäre und Datenschutz |
ALLDATASHEETDE.COM |
War ALLDATASHEET hilfreich? [ DONATE ] |
Über Alldatasheet | Werbung | Kontakt | Privatsphäre und Datenschutz | Linktausch | Hersteller All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |