6 / 12 page REV. B –6– AD7896 CONVERTER DETAILS The AD7896 is a fast, 12-bit A/D converter that operates from a single +2.7 V to +5.5 V supply. It provides the user with a track/ hold, A/D converter and serial interface logic functions on a single chip. The A/D converter section of the AD7896 consists of a conventional successive-approximation converter based around an R-2R ladder structure. The internal reference for the AD7896 is derived from VDD, and this allows the part to accept an analog input range of 0 V to VDD. The AD7896 has two op- erating modes, the high sampling mode and the auto sleep mode where the part automatically goes into sleep after the end of conversion. These modes are discussed in more detail in the Timing and Control section. A major advantage of the AD7896 is that it provides all of the above functions in an 8-pin package, either 8-pin mini-DIP or SOIC. This offers the user considerable space saving advan- tages over alternative solutions. The AD7896 consumes only 9 mW typical making it ideal for battery-powered applications. Conversion is initiated on the AD7896 by pulsing the CONVST input. On the falling edge of CONVST, the on-chip track/hold goes from track to hold mode and the conversion sequence is started. The conversion clock for the part is generated inter- nally using a laser-trimmed clock oscillator circuit. Conversion time for the AD7896 is 8 µs in the high sampling mode (14 µs for the auto sleep mode), and the track/hold acquisition time is 1.5 µs. To obtain optimum performance from the part, the read operation should not occur during the conversion or during 400 ns prior to the next conversion. This allows the part to op- erate at throughput rates up to 100 kHz and achieve data sheet specifications (see Timing and Control Section). CIRCUIT DESCRIPTION Analog Input Section The analog input range for the AD7896 is 0 V to VDD. The VIN pin drives the input to the track/hold amplifier directly. This al- lows for a maximum output impedance of the circuit driving the analog input of 1 k Ω. This ensures that the part will be settled to 12-bit accuracy in the 1.5 µs acquisition time. This input is benign with dynamic charging currents. The designed code transitions occur on successive integer LSB values (i.e., 1 LSB, 2 LSB, 3 LSB . . . FS–1 LSB). Output coding is straight (natu- ral) binary with 1 LSB = FS/4096 = 3.3 V/4096 = 0.81 mV. The ideal input/output transfer function is shown in Table I. Table I. Ideal Input/Output Code Table for the AD7896 Analog Input 1 Code Transition +FSR – 1 LSB 2 (3.299194) 111 . . . 110 to 111 . . . 111 +FSR – 2 LSB (3.298389) 111 . . . 101 to 111 . . . 110 +FSR/2 – 3 LSB (3.297583) 111 . . . 100 to 111 . . . 101 AGND + 3 LSB (0.002417) 000 . . . 010 to 000 . . . 011 AGND + 2 LSB (0.001611) 000 . . . 001 to 000 . . . 010 AGND + 1 LSB (0.000806) 000 . . . 000 to 000 . . . 001 NOTES 1FSR is full-scale range and is 3.3 V with V DD = +3.3 V. 21 LSB = FSR/4096 = 0.81 mV with V DD = +3.3 V. Track/Hold Section The track/hold amplifier on the analog input of the AD7896 al- lows the ADC to accurately convert an input sine wave of full- scale amplitude to 12-bit accuracy. The input bandwidth of the track/hold is greater than the Nyquist rate of the ADC even when the ADC is operated at its maximum throughput rate of 100 kHz (i.e., the track/hold can handle input frequencies in excess of 50 kHz). The track/hold amplifier acquires an input signal to 12-bit accu- racy in less than 1.5 µs. The operation of the track/hold is essen- tially transparent to the user. With the high sampling operating mode the track/hold amplifier goes from its tracking mode to its hold mode at the start of conversion (i.e., the rising edge of CONVST ). The aperture time for the track/hold (i.e., the delay time between the external CONVST signal and the track/hold actually going into hold) is typically 15 ns. At the end of conver- sion (on the falling edge of BUSY) the part returns to its tracking mode. The acquisition time of the track/hold amplifier begins at this point. For the auto shutdown mode, the rising edge of CONVST wakes up the part and the track and hold amplifier goes from its tracking mode to its hold mode 6 µs after the rising edge of CONVST ( provided that the CONVST high time is less then 6 µs). Once again the part returns to its tracking mode at the end of conversion when the BUSY signal goes low. Timing and Control Section Figure 2 shows the timing and control sequence required to ob- tain optimum performance from the AD7896. In the sequence shown, conversion is initiated on the falling edge of CONVST and new data from this conversion is available in the output reg- ister of the AD7896 8 µs later. Once the read operation has taken place, a further 400 ns should be allowed before the next falling edge of CONVST to optimize the settling of the track/ hold amplifier before the next conversion is initiated. With the serial clock frequency at its maximum of 10 MHz (5 V opera- tion), the achievable throughput rate for the part is 8 µs (conver- sion time) plus 1.6 µs (read time) plus 0.4 µs (acquisition time). This results in a minimum throughput time of 10 µs (equivalent to a throughput rate of 100 kHz). A serial clock of less than 10 MHz can be used but this will in turn mean that the throughput time will increase. The read operation consists of sixteen serial clock pulses to the output shift register of the AD7896. After sixteen serial clock pulses the shift register is reset and the SDATA line is three- stated. If there are more serial clock pulses after the sixteenth clock, the shift register will be moved on past its reset state. However, the shift register will be reset again on the falling edge of the CONVST signal to ensure that the part returns to a known state every conversion cycle. As a result, a read opera- tion from the output register should not straddle across the fall- ing edge of CONVST as the output shift register will be reset in the middle of the read operation and the data read back into the microprocessor will appear invalid. The throughput rate of the part can be increased by reading data during conversion. If the data is read during conversion, a throughput time of 8 µs (conversion time) plus 1.5 µs (acquisi- tion time) is achieved when a 10 MHz (5 V operation) serial clock is being used. This minimum throughput time of 9.5 µs is achieved with a slight reduction in performance from the AD7896. The advantage of this arrangement is that when the serial clock is significantly lower than 10 MHz the throughput time for this arrangement will be significantly less than the throughput time where the data is read after conversion. The Signal to (Noise + Distortion) number is likely to degrade by less than 1 dB while the code flicker from the part will also in- crease (see AD7896 PERFORMANCE section). |
Ähnliche Teilenummer - AD7896AR |
|
Ähnliche Beschreibung - AD7896AR |
|
|
Link URL |
Privatsphäre und Datenschutz |
ALLDATASHEETDE.COM |
War ALLDATASHEET hilfreich? [ DONATE ] |
Über Alldatasheet | Werbung | Kontakt | Privatsphäre und Datenschutz | Linktausch | Hersteller All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |