Datenblatt-Suchmaschine für elektronische Bauteile |
|
U1173A Datenblatt(PDF) 3 Page - Agilent(Hewlett-Packard) |
|
U1173A Datenblatt(HTML) 3 Page - Agilent(Hewlett-Packard) |
3 / 10 page 3 Electrical Specifications DC specifications Function Range Resolution Accuracy ± (% of reading + counts of least significant digit) Test current Burden voltage/ shunt Input impedance U1231A/U1232A/ U1233A Where (applicable) Where (applicable) Where (applicable) Voltage 600 mV1 0.1 mV 0.5% + 2 NA NA 11.18 MΩ 6 V 0.001 V 0.5% + 2 NA NA 11.18 MΩ 60 V 0.01 V 0.5% + 2 NA NA 10.1 MΩ 600 V 0.1 V 0.5% + 2 NA NA 10 MΩ 600 V (VZ LOW) 2 0.1 V 2% + 3 NA NA 3 kΩ Resistance 600 Ω4 0.1 Ω 0.9% + 3 0.57 mA NA NA 6 kΩ4 0.001 kΩ 0.9% + 3 57 μA NA NA 60 kΩ 0.01 kΩ 0.9% + 3 5.7 μA NA NA 600 kΩ 0.1 kΩ 0.9% + 3 570 nA NA NA 6 MΩ5 0.001 MΩ 0.9% + 3 100 nA/10 MΩ NA NA 60 MΩ5 0.01 MΩ 1.5% + 3 100 nA/10 MΩ NA NA Diode3 2 V 0.001 V 0.9% + 2 0.57 mA NA NA Current 60 μA1 0.01 μA 1.0% + 24 NA < 2.5 V/1 kΩ NA 600 μA1 0.1 μA 1.0% + 24 NA < 2.5 V/1 kΩ NA 6 A2 0.001 A 1.0% + 34 NA < 0.2 V/0.005 Ω NA 10 A2, 3 0.01 A 1.0% + 34 NA < 0.4 V/0.005 Ω NA Notes for DC voltage specifications: 1. The accuracy of the 600 mV range is specified after the Null function is used to subtract the thermal effect (by shorting the test leads). 2. For VZ LOW (low input impedance) measurements, auto-ranging is disabled and the multimeter’s range is set to 600 V in the manual ranging mode. Notes for resistance specifications: 1. Overload protection: 600 Vrms for short circuits with < 0.3 A current. 2. Maximum open voltage is < +3 V. 3. Built-in buzzer beeps when the resistance measured is less than 23 Ω ± 10 Ω. The multimeter can capture intermittent measurements longer than 1 ms. 4. The accuracy of the 600 Ω to 6 kΩ range is specified after the Null function is used to subtract the test lead resistance and thermal effect (by shorting the test leads). 5. For the ranges of 6 MΩ and 60 MΩ, the RH is specified for < 60%. Notes for diode specifications: 1. Overload protection: 600 Vrms for short circuits with < 0.3 A current. 2. Built-in buzzer beeps continuously when the voltage measured is less than 50 mV and beeps once for forward-biased diode or semiconductor junctions measured between 0.3 V and 0.8 V (0.3 V ≤ reading ≤ 0.8 V). 3. Open voltage for diode: < +3 V DC. 4. The maximum display for diode measurements is 2100 counts. Notes for DC current specifications: 1. Overload protection for 60 μA to 600 μA range: 600 Vrms for short circuits with < 0.3 A current. 2. Overload protection for 6 A to 10 A range: 11 A/1000 V; 10 × 38 mm fast-acting fuse. 3. Specification for 10 A range: 10 A continuous. Add 0.3% to the specified accuracy when measuring signals > 10 A to 20 A for 30 seconds maximum. After measuring currents > 10 A, cool down the multimeter for twice the duration of the measured time before proceeding with low current measurements. 4. Only applicable for the U1232/U1233 Series |
Ähnliche Teilenummer - U1173A |
|
Ähnliche Beschreibung - U1173A |
|
|
Link URL |
Privatsphäre und Datenschutz |
ALLDATASHEETDE.COM |
War ALLDATASHEET hilfreich? [ DONATE ] |
Über Alldatasheet | Werbung | Kontakt | Privatsphäre und Datenschutz | Linktausch | Hersteller All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |