Datenblatt-Suchmaschine für elektronische Bauteile |
|
SDN03264C1CF1MT-60 Datenblatt(PDF) 7 Page - List of Unclassifed Manufacturers |
|
SDN03264C1CF1MT-60 Datenblatt(HTML) 7 Page - List of Unclassifed Manufacturers |
7 / 13 page Data Sheet Rev.1.0 30.05.2012 Swissbit AG Industriestrasse 4 Fon: +41 (0) 71 913 03 03 www.swissbit.com Page 7 CH-9552 Bronschhofen Fax: +41 (0) 71 913 03 15 eMail: info@swissbit.com of 13 IDD Specifications AND CONDITIONS (0°C ≤ TA ≤ + 70°C; VDDQ = +2.5V ± 0.2V, VDD = +2.5V ± 0.2V) see Note 1 on Page 9 Parameter & Test Condition Symb. max. 3200-3033 2700-2533 Unit OPERATING CURRENT *) : One device bank; Active- Precharge; tRC= tRC (Min); tCK = tCK (Min); DQ, DM and DQS inputs changing once per clock cycle; Address and control inputs changing once every two clock cycles IDD0 620 520 mA OPERATING CURRENT :*) One device bank; Active-Read-Precharge; Burst = 2; tRC= tRC (Min); tCK = tCK (Min);IOUT = 0mA; Address and control inputs changing once per clock cycle IDD1 780 640 mA PRECHARGE POWER-DOWN STANDBY CURRENT: All device banks idle; Power-down mode; tCK = tCK (Min); CKE = (LOW) IDD2P 20 20 mA IDLE STANDBY CURRENT: CS# = HIGH; All device banks idle; tCK = tCK (Min); CKE= HIGH; Address and other control inputs changing once per clock cycle. VIN = VREF for DQ, DQS, and DM IDD2F 220 180 mA ACTIVE POWER-DOWN STANDBY CURRENT: One device bank active; Power-down mode; tCK = tCK (Min);CKE = LOW IDD3P 180 140 mA ACTIVE STANDBY CURRENT: CS# = HIGH; CKE = HIGH; One device bank; Active-Precharge; tRC= tRAS (Max); tCK = tCK (Min); DQ, DM and DQS inputs changing twice per clock cycle; Address and other control inputs changing once per clock cycle IDD3N 240 200 mA OPERATING CURRENT: Burst = 2; Reads; Continous burst; One bank active; Address and control inputs changing once per clock cycle; tCK = tCK (Min); IOUT = 0mA IDD4R 840 660 mA OPERATING CURRENT: Burst = 2; Writes; Continuous burst; One device bank active; Address and control inputs changing once per clock cycle; tCK = tCK (Min); DQ, DM, and DQS inputs changing twice per clock cycle IDD4W 860 780 mA AUTO REFRESH CURRENT tRC = tRC (Min) IDD5 1380 1160 mA tRC = 7.8125µs IDD5A 44 40 mA SELF REFRESH CURRENT: CKE ≤ 0.2V IDD6 24 20 mA OPERATING CURRENT*): Four device bank interleaving READs (BL =4) with auto precharge, tRC = tRC (Min); tCK = tCK (Min); Address and control inputs change only during Active READ, or WRITE commands IDD7 1920 1620 mA *) Value calculated as one module rank in this operating condition, and all other module ranks in IDD2P (CKE LOW) mode. |
Ähnliche Teilenummer - SDN03264C1CF1MT-60 |
|