Datenblatt-Suchmaschine für elektronische Bauteile |
|
U1165A Datenblatt(PDF) 6 Page - Agilent(Hewlett-Packard) |
|
U1165A Datenblatt(HTML) 6 Page - Agilent(Hewlett-Packard) |
6 / 19 page 6 U1251A/U1251B FREQUENCY SENSITIVITY DURING VOLTAGE MEASUREMENT FREQUENCY SENSITIVITY AND TRIGGER LEVEL INPUT RANGE MINIMUM SENSITIVITY (R.M.S. Sine Wave) TRIGGER LEVEL FOR DC COUPLING (Maximum input for specified accuracy = 10 x Range or 1000 V) 20 Hz - 100 kHz >100 kHz ~ 200 kHz < 100 kHz >100 kHz ~ 200 kHz 50.000 mV 10 mV 15 mV 10 mV 15 mV 500.00 mV 25 mV 35 mV 60 mV 70 mV 1000.0 mV 40 mV 50 mV 100 mV 150 mV 5.0000 V 0.25 V 0.5 V 0.5 V / 1.25 V (< 100 Hz) 0.6 V 50.000 V 2.5 V 5 V 5 V 6 V 500.00 V 25 V N/A 50 V N/A 1000.0 V 50 V N/A 300 V N/A U1252A/U1252B/U1253A/U1253B FREQUENCY SENSITIVITY DURING VOLTAGE MEASUREMENT FREQUENCY SENSITIVITY AND TRIGGER LEVEL INPUT RANGE MINIMUM SENSITIVITY (R.M.S. Sine Wave) TRIGGER LEVEL FOR DC COUPLING (Maximum input for specified accuracy = 10 x Range or 1000 V) 20 Hz ~ 200 kHz >200 kHz ~ 500 kHz < 100 kHz >100 kHz ~ 500 kHz 50.000 mV 10 mV 25 mV 10 mV 25 mV 500.00 mV 70 mV 150 mV 70 mV 150 mV 1000.0 mV 120 mV 300 mV 120 mV 300 mV 5.0000 V 0.3 V 1.2 V 0.6 V 1.5 V 50.000 V 3 V 5 V 6 V 15 V 500.00 V 30 V < 100 kHz N/A 60 V N/A 1000.0 V 50 V < 100 kHz N/A 120 V N/A RANGE RESOLUTION ACCURACY MIN. INPUT FREQUENCY U1251A/2A U1253A 99.999 Hz 0.001 Hz 0.02%+3[8] 0.02%+3[8] 1 Hz 999.99 Hz 0.01 Hz 0.02%+3, <600 kHz 0.02%+3, <600 kHz 9.9999 kHz 0.0001 kHz 99.999 kHz 0.001 kHz 999.99 kHz 0.01 kHz FREQUENCY SPECIFICATIONS[4] [1] Input impedance: Refer to Table A on page 8. [2] Crest factor ≤ 3.0 at full scale, 5.0 at half scale except the 1000 mV and 1000 V ranges where it is 1.5 at full scale, 3.0 at half scale. For non-sinusoidal waveform, add 0.1% of reading ± 0.3% of range. [3] The additional error to be added as frequency >20 kHz and signal input <10% of range: 3 counts of LSD per kHz. [4] The input signal is lower than 20,000,000 V-Hz (the product of voltage and frequency). [5] Input current >35 µArms. [6] Current can be measured from 2.5 A up to 10 A continuously. An additional 0.5% needs to be added to the specified accuracy if the signal measured is in the range of 10 A ~ 20 A for 30 seconds maximum. After measuring a current of >10 A, leave the meter to cool down for twice the measuring time used before application of low current measurement. [7] Input current < 3 Arms. [8] For non-square wave signals, add 5 counts. |
Ähnliche Teilenummer - U1165A |
|
Ähnliche Beschreibung - U1165A |
|
|
Link URL |
Privatsphäre und Datenschutz |
ALLDATASHEETDE.COM |
War ALLDATASHEET hilfreich? [ DONATE ] |
Über Alldatasheet | Werbung | Kontakt | Privatsphäre und Datenschutz | Linktausch | Hersteller All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |